Safe Operation and Maintenance of Circuit Breakers and Switchgear
Switchgear failures and switching errors are among the most serious electrical risks in any facility: they can cause arc flash injuries, long outages and damage to connected equipment. This programme gives electrical engineers and technicians the knowledge to operate, test and maintain circuit breakers and switchgear safely, and to plan maintenance based on condition and risk.
Circuit breakers and switchgear are expected to work reliably for decades, often after long periods without operation. When maintenance is postponed, mechanisms stiffen, contacts and connections overheat, insulation degrades and protection settings drift from what the system needs. At the same time, switching operations are carried out under pressure with incomplete procedures, unclear isolation points or missing arc flash information. Many serious incidents happen during routine switching, racking or testing.
This programme combines equipment knowledge with safe working practice. It starts with how circuit breakers and switchgear work and what the ratings mean, then covers safe operation and isolation, testing and diagnostics, planned and condition-based maintenance, and fault finding. The focus is on practical procedures, correct interpretation of test results and the decisions that keep people and equipment safe.
Built on recognised practice. The programme references the IEC 62271 series for high-voltage switchgear and controlgear, IEC 61439 for low-voltage switchgear assemblies, IEC 60947-2 for low-voltage circuit breakers, EN 50110 for the operation of electrical installations, NFPA 70E for electrical safety in the workplace, NFPA 70B for electrical equipment maintenance and IEEE 1584 for arc flash hazard calculations. Manufacturer instructions and the client's own safety rules take precedence on site.
Decisions this programme improves. Whether a switching operation can proceed safely and what protection is needed; how to confirm isolation before work; which tests to perform and how to judge results; whether to repair, retrofit or replace ageing switchgear; how to set maintenance intervals based on condition and criticality; and how to handle SF6 equipment responsibly.
How it is delivered. Twenty hours across five sessions, built around one running case: a medium-voltage substation feeding a critical facility, where participants prepare a switching programme, review arc flash labels, interpret breaker test results and plan maintenance for ageing panels. Exercises use sample test reports, single-line diagrams and maintenance records.
In-house option. For organisations, the programme can be tailored to your own switchgear types, safety rules, permit-to-work system and maintenance records, and delivered for operations, maintenance and protection teams together.
Who Should Attend
Objectives
Course Outline
Competencies
Live Online
Related Topics
Electrical faults found after energisation are expensive, dangerous and often avoidable: a missed wiring error, an untested protection setting or an unclear handover can damage equipment and delay operation. This programme gives engineers and technicians a structured method to plan, perform and document pre-commissioning tests, first energisation and on-load checks for HV and LV systems.
To equip electrical engineers and technical professionals with the skills and knowledge required to design, plan, and optimize electrical distribution networks—ensuring reliability, safety, scalability, and compliance with national and international standards.
Motors drive most of the energy use and many of the breakdowns in industrial and building plants, yet they are often selected on catalogue ratings and run until they fail. This programme gives engineers and technicians the practical knowledge to select, control, protect and maintain motors and variable speed drives for reliability and efficiency.